BLXRG - METALLIC CONDUCTOR-NICKEL PLATED ETP/OF/CDA
- MSDS: BLXRG
- Manufacturer: W L GORE AND ASSOCIATES INC
- Product Name: METALLIC CONDUCTOR-NICKEL PLATED ETP/OF/CDA
- National Stock Number: 5340-00N018012
Product Identification
Product ID:METALLIC CONDUCTOR-NICKEL PLATED ETP/OF/CDA
MSDS Date:01/11/1990
FSC:5340
NIIN:00N018012
MSDS Number: BLXRG
Responsible Party
PHOENIX, AZ 85044
US
Emergency Phone: 301-392-3700
Info Phone: 602-431-0077 302-738-4880
Preparer: MARTIN J. HEALY CIH
Cage: 0ADM8
Contractor
Telephone: 302-368-3700/ 703-527-3887
Cage: 17217
Ingredients
COPPER
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: >70%
OSHA PEL 0.1MG/M3 (FUME)
ACGIH TLV: 0.2MG/M3 (FUME)
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
NICKEL
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: <30%
OSHA PEL 1 MG/M3 (METAL)
ACGIH TLV: 1 MG/M3 (METAL)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC:SPECIALTY FINE WIRE IS
GENERALLY NOT CONSIDERED HAZARDOUS IN FORM SHIPPED. HOWEVER, IF
YOUR PROCESS INVOLVES GRINDING, MELTING, WELDING, CUTTING OR ANY
OTHER PROCESS THAT CAUSES A RELEAS E OF DUST, FUME OR GAS, IN
CONCENTRATIONS GREATER THAN ALLOWABLE EXPOS LIMITS, THE FOLLOWING
EFTS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL: CLASS 2 (NTP); CLASS 2B (IARC).
Effects of Overexposure:HLTH HAZ: MAY BE OBSERVED:ACUTE:METALLIC TASTE,
IRRITATION OF EYES, NOSE, THROAT & SKIN, NAUSEA, TIGHTNESS OF CHEST
& FEVER. CHRONIC:SKIN SENSITIZATION, NEUROLOGICAL DAMAGE &
RESPIRATORY DISEASE. INGE ST OF LG ENOUGH QTYS TO CAUSE ADVERSE
HEALTH EFFECTS UNLIKELY.
Medical Cond Aggravated by Exposure:SOME WORKERS MAY BE AFFECTED BY
PRE-EXISTING RESPIRATORY OR ALLERGIC CONDITIONS.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR & GET MD IMMED. GIVE CPR IF
NEEDED. CALL MD. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER.
IF IRRITATION OCCURES, CALL MD. INGEST:INDUCE VOMIT IF CONSCIOUS &
CALL MD. E YE:FLUSH THOROUGHLY W/WATER FOR AT LEAST 15 MIN, HOLDING
LIDS OPEN. CALL MD.
Fire Fighting
Flash Point:NOT FLAMMABLE
Extinguishing Media:METALLIC CONDUCTOR IS NOT FLAMMABLE. USE
EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:SHOVEL SOLID INTO CONTAINER. MINIMIZE DUST.
VACUUMING PREFERRED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:THIS PRODUCT CONTAINS ONE OR MORE CHEMICALS SUBJECT
TO THE REPORTING REQUIREMENTS OF SARA TITLE III SEC 313; STATE
RIGHT TO KNOW LAWS (MA,NJ,PA); AND/OR CALIF PROP 65.
Exposure Controls
Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY REQUIRED
UNDER ANTICIPATED CONDITIONS OF USE. IF RESPIRATORS ARE NECESSARY,
USE ONLY NIOSH/MSHA APPROVED RESPIRATORS.
Ventilation:USE LOCAL MECH EXHST VENT WHEN PROCESSING MATL. COULD
RELEASE DUSTS, FUMES OR GASES IN CONC >ALLOWABLE EXPOS LIMITS.
Protective Gloves:PROTECTIVE GLOVES RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PRODS: THESE CONSTITUENTS MAY INCLUDE OXIDES OF METALS,
CHROMATES, FLUORIDES, CO, CO2, OZONE & NOX.
Chemical Properties
HCC:N1
Evaporation Rate & Reference:NOT APPLICABLE.
Solubility in Water:INSOLUBLE
Appearance and Odor:METALIC CONDUCTOR, SERVE WIRE SHIELD, BRAID, FOIL
SHIELD. NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
ACETYLENE, STRONG ACIDS & BASES & OXIDIZING AGENTS SUCH AS HYDROGEN
PEROXIDE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES & GASES FROM WELDING/HIGH TEMP
CUTTING MAY CONTAIN CONSTITUENTS DIFFERENT THAN THOSE LISTED IN
INGRED. (SUPP DATA)
Disposal
Waste Disposal Methods:DISPOSE OF ACCUMULATED WASTE I/A/W APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.